Designing an Acid-Base Titration
- Page ID
- 282779
\( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)
\( \newcommand{\dsum}{\displaystyle\sum\limits} \)
\( \newcommand{\dint}{\displaystyle\int\limits} \)
\( \newcommand{\dlim}{\displaystyle\lim\limits} \)
\( \newcommand{\id}{\mathrm{id}}\) \( \newcommand{\Span}{\mathrm{span}}\)
( \newcommand{\kernel}{\mathrm{null}\,}\) \( \newcommand{\range}{\mathrm{range}\,}\)
\( \newcommand{\RealPart}{\mathrm{Re}}\) \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)
\( \newcommand{\Argument}{\mathrm{Arg}}\) \( \newcommand{\norm}[1]{\| #1 \|}\)
\( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)
\( \newcommand{\Span}{\mathrm{span}}\)
\( \newcommand{\id}{\mathrm{id}}\)
\( \newcommand{\Span}{\mathrm{span}}\)
\( \newcommand{\kernel}{\mathrm{null}\,}\)
\( \newcommand{\range}{\mathrm{range}\,}\)
\( \newcommand{\RealPart}{\mathrm{Re}}\)
\( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)
\( \newcommand{\Argument}{\mathrm{Arg}}\)
\( \newcommand{\norm}[1]{\| #1 \|}\)
\( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)
\( \newcommand{\Span}{\mathrm{span}}\) \( \newcommand{\AA}{\unicode[.8,0]{x212B}}\)
\( \newcommand{\vectorA}[1]{\vec{#1}} % arrow\)
\( \newcommand{\vectorAt}[1]{\vec{\text{#1}}} % arrow\)
\( \newcommand{\vectorB}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\( \newcommand{\vectorC}[1]{\textbf{#1}} \)
\( \newcommand{\vectorD}[1]{\overrightarrow{#1}} \)
\( \newcommand{\vectorDt}[1]{\overrightarrow{\text{#1}}} \)
\( \newcommand{\vectE}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash{\mathbf {#1}}}} \)
\( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\(\newcommand{\longvect}{\overrightarrow}\)
\( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)
\(\newcommand{\ket}[1]{\left| #1 \right>}\)
\(\newcommand{\bra}[1]{\left< #1 \right|}\)
\(\newcommand{\braket}[2]{\left< #1 \vphantom{#2} \right| \left. #2 \vphantom{#1} \right>}\)
\(\newcommand{\braopket}[3]{\left< #1 \vphantom{#2}\vphantom{#3} \right| #2 \vphantom{#1}\vphantom{#3} \left| #3 \vphantom{#1}\vphantom{#2} \right>}\)
\(\newcommand{\qmvec}[1]{\mathbf{\vec{#1}}}\)
\(\newcommand{\op}[1]{\hat{\mathbf{#1}}}\)
\(\newcommand{\expect}[1]{\langle #1 \rangle}\)
\(\newcommand{\dfn}[1]{\emph{\textbf{#1}}}\)
Follow the link below to the Designing an Acid-Base Titration module.1
https://dthdpu.shinyapps.io/TitrationApp/
- Click on the Investigation 1 tab at the top of the page.
- Describe the effect of adjusting the initial [analyte] on the titration curve using the [titrant] = initial [analyte] setting.
- Describe the effect of adjusting the initial [analyte] on the titration curve after you deselect the [titrant] = initial [analyte] setting.
- Describe the effect of adjusting the analyte initial volume keeping all other variables the same.
- Set the initial [analyte] and [titrant] = 0.10 M, and initial volume = 50.0 mL. Determine which indicators would be effective, with minimal titration error, for determination of the end point.
- Now select strong base for the analyte, and adjust the variables to see how the titration curve varies.
- Click on the Investigation 2 tab at the top of the page.
- Describe the effect of changing the pKa of the weak acid.
- Describe the effect of adjusting the initial [analyte] on the titration curve using the [titrant] = initial [analyte] setting.
- Describe the effect of adjusting the initial [analyte] on the titration curve after you deselect the [titrant] = initial [analyte] setting.
- Describe the effect of adjusting the analyte initial volume keeping all other variables the same.
- Set the pKa = 5, the initial [analyte] and [titrant] = 0.10 M, and initial volume = 50.0 mL. Determine which indicators would be effective, with minimal titration error, for determination of the end point.
- Now select weak base for the analyte, and adjust the variables to see how the titration curve and indicator selection varies.
- You are given a 5.0 mM solution of 2,4-dinitrophenol (pKa = 4.114). Design a titration for which you can observe the end point within a 50 mL titrant range. Select an initial [analyte], initial analyte volume, [titrant], and indicator.
- Click on the Investigation 3 tab at the top of the page.
- Use the module to help you design a titration for maleic acid (cis-butenedioic acid) for which you can observe both end points within a 50 mL titrant range. Select an initial [analyte], initial analyte volume, [titrant], and an indicator for each of the 2 end points.
Contributors and Attributions
- Susan Oxley, St. Mary’s University (San Antonio) (soxley@stmarytx.edu)
- Sourced from the Analytical Sciences Digital Library
[1] Harvey, David. “Designing an Acid-Base Titration.” Analytical Sciences Digital Library.


