12.1: Molar Mass Determination Using Freezing Point Depression - Experiment
- Page ID
- 547486
\( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)
\( \newcommand{\dsum}{\displaystyle\sum\limits} \)
\( \newcommand{\dint}{\displaystyle\int\limits} \)
\( \newcommand{\dlim}{\displaystyle\lim\limits} \)
\( \newcommand{\id}{\mathrm{id}}\) \( \newcommand{\Span}{\mathrm{span}}\)
( \newcommand{\kernel}{\mathrm{null}\,}\) \( \newcommand{\range}{\mathrm{range}\,}\)
\( \newcommand{\RealPart}{\mathrm{Re}}\) \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)
\( \newcommand{\Argument}{\mathrm{Arg}}\) \( \newcommand{\norm}[1]{\| #1 \|}\)
\( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)
\( \newcommand{\Span}{\mathrm{span}}\)
\( \newcommand{\id}{\mathrm{id}}\)
\( \newcommand{\Span}{\mathrm{span}}\)
\( \newcommand{\kernel}{\mathrm{null}\,}\)
\( \newcommand{\range}{\mathrm{range}\,}\)
\( \newcommand{\RealPart}{\mathrm{Re}}\)
\( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)
\( \newcommand{\Argument}{\mathrm{Arg}}\)
\( \newcommand{\norm}[1]{\| #1 \|}\)
\( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)
\( \newcommand{\Span}{\mathrm{span}}\) \( \newcommand{\AA}{\unicode[.8,0]{x212B}}\)
\( \newcommand{\vectorA}[1]{\vec{#1}} % arrow\)
\( \newcommand{\vectorAt}[1]{\vec{\text{#1}}} % arrow\)
\( \newcommand{\vectorB}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\( \newcommand{\vectorC}[1]{\textbf{#1}} \)
\( \newcommand{\vectorD}[1]{\overrightarrow{#1}} \)
\( \newcommand{\vectorDt}[1]{\overrightarrow{\text{#1}}} \)
\( \newcommand{\vectE}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash{\mathbf {#1}}}} \)
\( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\(\newcommand{\longvect}{\overrightarrow}\)
\( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)
\(\newcommand{\ket}[1]{\left| #1 \right>}\)
\(\newcommand{\bra}[1]{\left< #1 \right|}\)
\(\newcommand{\braket}[2]{\left< #1 \vphantom{#2} \right| \left. #2 \vphantom{#1} \right>}\)
\(\newcommand{\braopket}[3]{\left< #1 \vphantom{#2}\vphantom{#3} \right| #2 \vphantom{#1}\vphantom{#3} \left| #3 \vphantom{#1}\vphantom{#2} \right>}\)
\(\newcommand{\qmvec}[1]{\mathbf{\vec{#1}}}\)
\(\newcommand{\op}[1]{\hat{\mathbf{#1}}}\)
\(\newcommand{\expect}[1]{\langle #1 \rangle}\)
\(\newcommand{\dfn}[1]{\emph{\textbf{#1}}}\)
\(\newcommand{\avec}{\mathbf a}\) \(\newcommand{\bvec}{\mathbf b}\) \(\newcommand{\cvec}{\mathbf c}\) \(\newcommand{\dvec}{\mathbf d}\) \(\newcommand{\dtil}{\widetilde{\mathbf d}}\) \(\newcommand{\evec}{\mathbf e}\) \(\newcommand{\fvec}{\mathbf f}\) \(\newcommand{\nvec}{\mathbf n}\) \(\newcommand{\pvec}{\mathbf p}\) \(\newcommand{\qvec}{\mathbf q}\) \(\newcommand{\svec}{\mathbf s}\) \(\newcommand{\tvec}{\mathbf t}\) \(\newcommand{\uvec}{\mathbf u}\) \(\newcommand{\vvec}{\mathbf v}\) \(\newcommand{\wvec}{\mathbf w}\) \(\newcommand{\xvec}{\mathbf x}\) \(\newcommand{\yvec}{\mathbf y}\) \(\newcommand{\zvec}{\mathbf z}\) \(\newcommand{\rvec}{\mathbf r}\) \(\newcommand{\mvec}{\mathbf m}\) \(\newcommand{\zerovec}{\mathbf 0}\) \(\newcommand{\onevec}{\mathbf 1}\) \(\newcommand{\real}{\mathbb R}\) \(\newcommand{\twovec}[2]{\left[\begin{array}{r}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\ctwovec}[2]{\left[\begin{array}{c}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\threevec}[3]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\cthreevec}[3]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\fourvec}[4]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\cfourvec}[4]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\fivevec}[5]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\cfivevec}[5]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\mattwo}[4]{\left[\begin{array}{rr}#1 \amp #2 \\ #3 \amp #4 \\ \end{array}\right]}\) \(\newcommand{\laspan}[1]{\text{Span}\{#1\}}\) \(\newcommand{\bcal}{\cal B}\) \(\newcommand{\ccal}{\cal C}\) \(\newcommand{\scal}{\cal S}\) \(\newcommand{\wcal}{\cal W}\) \(\newcommand{\ecal}{\cal E}\) \(\newcommand{\coords}[2]{\left\{#1\right\}_{#2}}\) \(\newcommand{\gray}[1]{\color{gray}{#1}}\) \(\newcommand{\lgray}[1]{\color{lightgray}{#1}}\) \(\newcommand{\rank}{\operatorname{rank}}\) \(\newcommand{\row}{\text{Row}}\) \(\newcommand{\col}{\text{Col}}\) \(\renewcommand{\row}{\text{Row}}\) \(\newcommand{\nul}{\text{Nul}}\) \(\newcommand{\var}{\text{Var}}\) \(\newcommand{\corr}{\text{corr}}\) \(\newcommand{\len}[1]{\left|#1\right|}\) \(\newcommand{\bbar}{\overline{\bvec}}\) \(\newcommand{\bhat}{\widehat{\bvec}}\) \(\newcommand{\bperp}{\bvec^\perp}\) \(\newcommand{\xhat}{\widehat{\xvec}}\) \(\newcommand{\vhat}{\widehat{\vvec}}\) \(\newcommand{\uhat}{\widehat{\uvec}}\) \(\newcommand{\what}{\widehat{\wvec}}\) \(\newcommand{\Sighat}{\widehat{\Sigma}}\) \(\newcommand{\lt}{<}\) \(\newcommand{\gt}{>}\) \(\newcommand{\amp}{&}\) \(\definecolor{fillinmathshade}{gray}{0.9}\)
- Always wear chemical splash goggles and a lab coat in the laboratory.
- Exercise extreme caution when handling hot equipment, hot plates, and test tubes containing molten organic compounds.
- Avoid direct skin contact with hot lauric acid or benzoic acid, which can cause THERMAL BURNS or mild skin irritation.
- Handle all glass test tubes and temperature probes with care to prevent breakage.
EQUIPMENT AND CHEMICALS NEEDED
| Hardware & Equipment | Hardware & Equipment | Chemicals & Solvents |
|---|---|---|
| Vernier LabQuest interface | Ring stand & utility clamp | Lauric acid (solvent) |
| Stainless Steel Temperature Probe | Large test tubes (25 mm × 150 mm) | Benzoic acid (solute) |
| 400-mL beaker (water bath) | Paper towels & wire stirrer | Tap water (cooling bath) |
| Hot plate | Electronic balance (±0.001 g) |
EXPERIMENTAL PROCEDURE
Part A: Set Up and Configure Data Collection
1. Configure Collection Parameters
- Connect the Stainless Steel Temperature Probe to CH 1 on the LabQuest interface.
- Tap Mode on the screen.
- Set Duration to 1200 s (20 minutes) and Rate to 1 sample/second.
- Tap OK.
2. Adjust Graph Display Axes
- Tap the Y-axis (Temperature) scale values.
- Set Top to 100 °C and Bottom to 0 °C.
- This scaling ensures the full phase-change curve is visible without manual scrolling.
Part B: Determine the Freezing Point of Pure Lauric Acid
- Fill a 400-mL beaker with approximately 300 mL of room-temperature tap water (20–25 °C) and place it on a ring stand setup.
Figure \(\PageIndex{1}\): Freezing Point Depression Experimental Setup - Obtain a test tube containing melted pure lauric acid from the instructor's hot water bath and clamp it securely using a utility clamp.
- Insert the temperature probe into the liquid lauric acid and allow it to equilibrate for 45 seconds. Keep the test tube suspended above the water bath.
- Start data collection on the LabQuest interface.
- Lower the test tube into the water bath so the water level is higher than the lauric acid level in the tube. If the initial lauric acid temperature drops below 50 °C before immersion, return it to the hot bath to remelt.
- Gently move the temperature probe up and down in a continuous motion to stir the liquid as it cools. Continue collecting data for 20 minutes.
- After data collection is complete, raise the test tube out of the water bath and remove the beaker of water (reserve the water for Part C).
- Return the test tube to the hot water bath to melt the solid lauric acid. Do not force the probe out while solid. Once melted, carefully wipe the probe with a paper towel.
- Analyze the plateau region on the cooling curve to locate the precise freezing point.
Pure Solvent (Plateau Method)
- Identify the flat, horizontal plateau where temperature remains constant during phase change.
- Drag to highlight only the flat plateau region on the graph.
- Tap Analyze → Statistics.
- Record the Mean temperature as the freezing point (Tf,solvent).
Figure \(\PageIndex{2}\): Cooling curve for pure lauric acid featuring a constant-temperature freezing plateau. - Record the mean plateau temperature as the freezing point of pure lauric acid on your report sheet. Save the LabQuest data file.
Part C: Freezing Point of a Benzoic-Acid/Lauric-Acid Solution
- Obtain a test tube containing a melted mixture of approximately 1.0 g benzoic acid in 8.0 g lauric acid.
- Record the exact masses of lauric acid and benzoic acid from the container label or instructor's data log.
- Repeat Steps 2–8 from Part B to record the cooling curve for the solution.
- Identify the freezing point from the solution cooling curve.
Solution (Break Point Method)
- Solutions do not exhibit a flat plateau; the cooling curve continues sloping downward as concentration increases during freezing.
- Locate the Break Point: the sharp change in slope where rapid liquid cooling transitions into a shallower freezing line.
- Tap that exact break point on the curve to read the freezing temperature (Tf,solution).
Figure \(\PageIndex{3}\): Solution cooling curve showing the break point marking the onset of freezing. - Record the break-point temperature as the freezing point of the solution (Tf,solution).
- Return all test tubes containing lauric acid and lauric-acid/benzoic-acid mixtures to the designated collection rack in the hot water bath. Do not pour organic chemicals down the drain.
- Dispose of water bath water into the laboratory sink. Clean all equipment before storing.


