9.1: Experimental Determination of the Ideal Gas Constant - Experiment
- Page ID
- 547474
\( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)
\( \newcommand{\dsum}{\displaystyle\sum\limits} \)
\( \newcommand{\dint}{\displaystyle\int\limits} \)
\( \newcommand{\dlim}{\displaystyle\lim\limits} \)
\( \newcommand{\id}{\mathrm{id}}\) \( \newcommand{\Span}{\mathrm{span}}\)
( \newcommand{\kernel}{\mathrm{null}\,}\) \( \newcommand{\range}{\mathrm{range}\,}\)
\( \newcommand{\RealPart}{\mathrm{Re}}\) \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)
\( \newcommand{\Argument}{\mathrm{Arg}}\) \( \newcommand{\norm}[1]{\| #1 \|}\)
\( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)
\( \newcommand{\Span}{\mathrm{span}}\)
\( \newcommand{\id}{\mathrm{id}}\)
\( \newcommand{\Span}{\mathrm{span}}\)
\( \newcommand{\kernel}{\mathrm{null}\,}\)
\( \newcommand{\range}{\mathrm{range}\,}\)
\( \newcommand{\RealPart}{\mathrm{Re}}\)
\( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)
\( \newcommand{\Argument}{\mathrm{Arg}}\)
\( \newcommand{\norm}[1]{\| #1 \|}\)
\( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)
\( \newcommand{\Span}{\mathrm{span}}\) \( \newcommand{\AA}{\unicode[.8,0]{x212B}}\)
\( \newcommand{\vectorA}[1]{\vec{#1}} % arrow\)
\( \newcommand{\vectorAt}[1]{\vec{\text{#1}}} % arrow\)
\( \newcommand{\vectorB}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\( \newcommand{\vectorC}[1]{\textbf{#1}} \)
\( \newcommand{\vectorD}[1]{\overrightarrow{#1}} \)
\( \newcommand{\vectorDt}[1]{\overrightarrow{\text{#1}}} \)
\( \newcommand{\vectE}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash{\mathbf {#1}}}} \)
\( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\(\newcommand{\longvect}{\overrightarrow}\)
\( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)
\(\newcommand{\ket}[1]{\left| #1 \right>}\)
\(\newcommand{\bra}[1]{\left< #1 \right|}\)
\(\newcommand{\braket}[2]{\left< #1 \vphantom{#2} \right| \left. #2 \vphantom{#1} \right>}\)
\(\newcommand{\braopket}[3]{\left< #1 \vphantom{#2}\vphantom{#3} \right| #2 \vphantom{#1}\vphantom{#3} \left| #3 \vphantom{#1}\vphantom{#2} \right>}\)
\(\newcommand{\qmvec}[1]{\mathbf{\vec{#1}}}\)
\(\newcommand{\op}[1]{\hat{\mathbf{#1}}}\)
\(\newcommand{\expect}[1]{\langle #1 \rangle}\)
\(\newcommand{\dfn}[1]{\emph{\textbf{#1}}}\)
\(\newcommand{\avec}{\mathbf a}\) \(\newcommand{\bvec}{\mathbf b}\) \(\newcommand{\cvec}{\mathbf c}\) \(\newcommand{\dvec}{\mathbf d}\) \(\newcommand{\dtil}{\widetilde{\mathbf d}}\) \(\newcommand{\evec}{\mathbf e}\) \(\newcommand{\fvec}{\mathbf f}\) \(\newcommand{\nvec}{\mathbf n}\) \(\newcommand{\pvec}{\mathbf p}\) \(\newcommand{\qvec}{\mathbf q}\) \(\newcommand{\svec}{\mathbf s}\) \(\newcommand{\tvec}{\mathbf t}\) \(\newcommand{\uvec}{\mathbf u}\) \(\newcommand{\vvec}{\mathbf v}\) \(\newcommand{\wvec}{\mathbf w}\) \(\newcommand{\xvec}{\mathbf x}\) \(\newcommand{\yvec}{\mathbf y}\) \(\newcommand{\zvec}{\mathbf z}\) \(\newcommand{\rvec}{\mathbf r}\) \(\newcommand{\mvec}{\mathbf m}\) \(\newcommand{\zerovec}{\mathbf 0}\) \(\newcommand{\onevec}{\mathbf 1}\) \(\newcommand{\real}{\mathbb R}\) \(\newcommand{\twovec}[2]{\left[\begin{array}{r}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\ctwovec}[2]{\left[\begin{array}{c}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\threevec}[3]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\cthreevec}[3]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\fourvec}[4]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\cfourvec}[4]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\fivevec}[5]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\cfivevec}[5]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\mattwo}[4]{\left[\begin{array}{rr}#1 \amp #2 \\ #3 \amp #4 \\ \end{array}\right]}\) \(\newcommand{\laspan}[1]{\text{Span}\{#1\}}\) \(\newcommand{\bcal}{\cal B}\) \(\newcommand{\ccal}{\cal C}\) \(\newcommand{\scal}{\cal S}\) \(\newcommand{\wcal}{\cal W}\) \(\newcommand{\ecal}{\cal E}\) \(\newcommand{\coords}[2]{\left\{#1\right\}_{#2}}\) \(\newcommand{\gray}[1]{\color{gray}{#1}}\) \(\newcommand{\lgray}[1]{\color{lightgray}{#1}}\) \(\newcommand{\rank}{\operatorname{rank}}\) \(\newcommand{\row}{\text{Row}}\) \(\newcommand{\col}{\text{Col}}\) \(\renewcommand{\row}{\text{Row}}\) \(\newcommand{\nul}{\text{Nul}}\) \(\newcommand{\var}{\text{Var}}\) \(\newcommand{\corr}{\text{corr}}\) \(\newcommand{\len}[1]{\left|#1\right|}\) \(\newcommand{\bbar}{\overline{\bvec}}\) \(\newcommand{\bhat}{\widehat{\bvec}}\) \(\newcommand{\bperp}{\bvec^\perp}\) \(\newcommand{\xhat}{\widehat{\xvec}}\) \(\newcommand{\vhat}{\widehat{\vvec}}\) \(\newcommand{\uhat}{\widehat{\uvec}}\) \(\newcommand{\what}{\widehat{\wvec}}\) \(\newcommand{\Sighat}{\widehat{\Sigma}}\) \(\newcommand{\lt}{<}\) \(\newcommand{\gt}{>}\) \(\newcommand{\amp}{&}\) \(\definecolor{fillinmathshade}{gray}{0.9}\)
- Always wear chemical splash goggles and a lab coat in the laboratory.
- You will be using an open Bunsen burner flame. Keep all flammable materials, paper, and hair away from the heat source.
- Heated glassware remains hot for an extended period and can cause severe burns. Allow the test tube and apparatus to cool completely before touching.
- Ensure all stopper connections are tight to prevent hot gas or pressure build-up leaks.
EQUIPMENT AND CHEMICALS NEEDED
| Equipment & Hardware | Chemicals & Supplies |
|---|---|
| Ring stand and utility clamp | Bunsen burner & striker |
| Large hard-glass test tube | Pinch clamp & rubber tubing |
| 1-hole rubber stopper for test tube | 400-mL beaker |
| Glass tubing assemblies (bent glass tubes) | 250-mL graduated cylinder |
| 500-mL Florence flask (or side-arm vacuum flask) | Thermometer or temperature probe |
| 2-hole stopper for Florence flask | Laboratory barometer |
| Large rubber bulb or pipet pump | Sodium bicarbonate (NaHCO3) |
EXPERIMENTAL PROCEDURE
Part A: Assemble the Apparatus
Goal: Establish a continuous, leak-free water siphon between the flask and the beaker.
- Assemble the gas displacement apparatus as shown in Figure \(\PageIndex{1}\).
Figure \(\PageIndex{1}\): Experimental apparatus setup. - Fill the flask almost completely to the top with water and open the pinch clamp on the delivery tubing.
- Remove the rubber stopper from the empty test tube.
Figure \(\PageIndex{2}\): Siphon Setup. - Using a large pipet pump, gently apply air pressure through the test tube stopper until the delivery hose is filled with water and flows into the beaker, creating a continuous siphon.
- Reinsert the stopper into the test tube while water is flowing. If the system is airtight, water flow will cease immediately. If water continues to flow, a leak is present; press all stoppers firmly. Ask your instructor if leaks persist.
- Close the pinch clamp on the rubber hose while it remains filled with water. Do not drain the hose.
- Remove the stopper from the test tube.
Part B: Prepare the Sample and Flask
Goal: Prepare the chemical sample and initialize the water level in the flask.
- Ensure the large test tube is completely clean and dry inside.
- Accurately weigh approximately 1.20 g of sodium bicarbonate on an analytical balance. Record the exact mass in the Data Table. Transfer the solid into the dry test tube. Do not attach the test tube stopper yet.
- Fill the 400-mL beaker about half full with water.
- Refill the flask: Open the pinch clamp and raise the beaker above the flask level so water siphons back in. Fill the flask until the water level reaches about 1 cm below the internal glass tubing.
- Close the pinch clamp while keeping the hose submerged.
Part C: Equalize Initial System Pressure
Goal: Ensure initial internal system pressure matches room atmospheric pressure (Patm).
- Seal the System: Firmly press the rubber stopper into the test tube containing the sample.
- Open the Line: Open the pinch clamp.
- Leveling: Manually raise or lower the beaker until the water level (meniscus) in the beaker is at the same height as the water level in the flask (Figure \(\PageIndex{2}\)). When levels match, internal pressure equals atmospheric pressure.
- Lock Pressure: Holding the beaker steady at this height, close the pinch clamp.
Part D: Final Setup for Gas Collection
Goal: Prepare the beaker for water collection without breaking the liquid siphon.
- Empty the Beaker: Pour out the water from the beaker. Do not dry the inside; residual droplets will not affect measurements. Crucial: Keep the rubber hose filled with water.
- Position Hose: Place the empty beaker back on the lab bench and position the end of the rubber hose deep inside the beaker.
- Open System: Open the pinch clamp. A small amount of water may flow into the beaker or flask until equilibrium is reached; do not empty the beaker again.
Part E: Decompose Sodium Bicarbonate
Goal: Thermally decompose the sample to generate carbon dioxide gas.
- Light the Bunsen burner. Gently heat the test tube containing the NaHCO3 by moving the flame back and forth along the tube. After 1 minute of gentle heating, apply direct heat to the sample.
- Observe carbon dioxide evolution as displaced water flows into the beaker. Continue strong heating until gas evolution ceases completely.
- Remove the Bunsen burner flame and allow the entire apparatus to cool to room temperature (15–20 minutes).
Part F: Equalize Final System Pressure
Goal: Equalize final pressure to ensure collected volume reflects gas produced at atmospheric pressure.
- Cooling Check: Verify the test tube has cooled completely to room temperature. Equalizing while gas is warm will introduce significant volume error upon cooling.
- Final Leveling: Raise or lower the beaker until the water level in the beaker matches the water level in the flask exactly.
- Final Seal: While keeping the water levels aligned, close the pinch clamp to trap the exact volume of displaced water at atmospheric pressure. At this point: Ptotal = PCO2 + PH2O = Patm.
- Remove the rubber hose from the beaker.
Part G: Measure Displaced Water and Conditions
Goal: Measure displaced water volume, temperature, and atmospheric pressure.
- Measure the volume of water collected in the beaker using a 250-mL graduated cylinder. Record this volume to the nearest 0.5 mL.
- Measure and record the temperature of the water in the beaker. This corresponds to the gas temperature (Tlab) used to look up water vapor pressure.
- Read and record the laboratory barometric pressure (Patm).
Part H: Repeat for Trial 2
- Clean the test tube, dry it thoroughly, and repeat the complete procedure (Parts A–G) with a second sample of sodium bicarbonate.
- Dispose of solid sodium carbonate residue from the test tube in the designated SOLID CHEMICAL WASTE container.
- Pour excess water down the laboratory drain. Clean all glassware before returning it.


