Skip to main content
Chemistry LibreTexts

9.1: Experimental Determination of the Ideal Gas Constant - Experiment

  • Page ID
    547474
  • ​

    ​

    \( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)

    \( \newcommand{\dsum}{\displaystyle\sum\limits} \)

    \( \newcommand{\dint}{\displaystyle\int\limits} \)

    \( \newcommand{\dlim}{\displaystyle\lim\limits} \)

    \( \newcommand{\id}{\mathrm{id}}\) \( \newcommand{\Span}{\mathrm{span}}\)

    ( \newcommand{\kernel}{\mathrm{null}\,}\) \( \newcommand{\range}{\mathrm{range}\,}\)

    \( \newcommand{\RealPart}{\mathrm{Re}}\) \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)

    \( \newcommand{\Argument}{\mathrm{Arg}}\) \( \newcommand{\norm}[1]{\| #1 \|}\)

    \( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)

    \( \newcommand{\Span}{\mathrm{span}}\)

    \( \newcommand{\id}{\mathrm{id}}\)

    \( \newcommand{\Span}{\mathrm{span}}\)

    \( \newcommand{\kernel}{\mathrm{null}\,}\)

    \( \newcommand{\range}{\mathrm{range}\,}\)

    \( \newcommand{\RealPart}{\mathrm{Re}}\)

    \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)

    \( \newcommand{\Argument}{\mathrm{Arg}}\)

    \( \newcommand{\norm}[1]{\| #1 \|}\)

    \( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)

    \( \newcommand{\Span}{\mathrm{span}}\) \( \newcommand{\AA}{\unicode[.8,0]{x212B}}\)

    \( \newcommand{\vectorA}[1]{\vec{#1}}      % arrow\)

    \( \newcommand{\vectorAt}[1]{\vec{\text{#1}}}      % arrow\)

    \( \newcommand{\vectorB}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \( \newcommand{\vectorC}[1]{\textbf{#1}} \)

    \( \newcommand{\vectorD}[1]{\overrightarrow{#1}} \)

    \( \newcommand{\vectorDt}[1]{\overrightarrow{\text{#1}}} \)

    \( \newcommand{\vectE}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash{\mathbf {#1}}}} \)

    \( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \(\newcommand{\longvect}{\overrightarrow}\)

    \( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)

    \(\newcommand{\ket}[1]{\left| #1 \right>}\)
    \(\newcommand{\bra}[1]{\left< #1 \right|}\)
    \(\newcommand{\braket}[2]{\left< #1 \vphantom{#2} \right| \left. #2 \vphantom{#1} \right>}\)
    \(\newcommand{\braopket}[3]{\left< #1 \vphantom{#2}\vphantom{#3} \right| #2 \vphantom{#1}\vphantom{#3} \left| #3 \vphantom{#1}\vphantom{#2} \right>}\)
    \(\newcommand{\qmvec}[1]{\mathbf{\vec{#1}}}\)
    \(\newcommand{\op}[1]{\hat{\mathbf{#1}}}\)
    \(\newcommand{\expect}[1]{\langle #1 \rangle}\)
    \(\newcommand{\dfn}[1]{\emph{\textbf{#1}}}\)

    \(\newcommand{\avec}{\mathbf a}\) \(\newcommand{\bvec}{\mathbf b}\) \(\newcommand{\cvec}{\mathbf c}\) \(\newcommand{\dvec}{\mathbf d}\) \(\newcommand{\dtil}{\widetilde{\mathbf d}}\) \(\newcommand{\evec}{\mathbf e}\) \(\newcommand{\fvec}{\mathbf f}\) \(\newcommand{\nvec}{\mathbf n}\) \(\newcommand{\pvec}{\mathbf p}\) \(\newcommand{\qvec}{\mathbf q}\) \(\newcommand{\svec}{\mathbf s}\) \(\newcommand{\tvec}{\mathbf t}\) \(\newcommand{\uvec}{\mathbf u}\) \(\newcommand{\vvec}{\mathbf v}\) \(\newcommand{\wvec}{\mathbf w}\) \(\newcommand{\xvec}{\mathbf x}\) \(\newcommand{\yvec}{\mathbf y}\) \(\newcommand{\zvec}{\mathbf z}\) \(\newcommand{\rvec}{\mathbf r}\) \(\newcommand{\mvec}{\mathbf m}\) \(\newcommand{\zerovec}{\mathbf 0}\) \(\newcommand{\onevec}{\mathbf 1}\) \(\newcommand{\real}{\mathbb R}\) \(\newcommand{\twovec}[2]{\left[\begin{array}{r}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\ctwovec}[2]{\left[\begin{array}{c}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\threevec}[3]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\cthreevec}[3]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\fourvec}[4]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\cfourvec}[4]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\fivevec}[5]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\cfivevec}[5]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\mattwo}[4]{\left[\begin{array}{rr}#1 \amp #2 \\ #3 \amp #4 \\ \end{array}\right]}\) \(\newcommand{\laspan}[1]{\text{Span}\{#1\}}\) \(\newcommand{\bcal}{\cal B}\) \(\newcommand{\ccal}{\cal C}\) \(\newcommand{\scal}{\cal S}\) \(\newcommand{\wcal}{\cal W}\) \(\newcommand{\ecal}{\cal E}\) \(\newcommand{\coords}[2]{\left\{#1\right\}_{#2}}\) \(\newcommand{\gray}[1]{\color{gray}{#1}}\) \(\newcommand{\lgray}[1]{\color{lightgray}{#1}}\) \(\newcommand{\rank}{\operatorname{rank}}\) \(\newcommand{\row}{\text{Row}}\) \(\newcommand{\col}{\text{Col}}\) \(\renewcommand{\row}{\text{Row}}\) \(\newcommand{\nul}{\text{Nul}}\) \(\newcommand{\var}{\text{Var}}\) \(\newcommand{\corr}{\text{corr}}\) \(\newcommand{\len}[1]{\left|#1\right|}\) \(\newcommand{\bbar}{\overline{\bvec}}\) \(\newcommand{\bhat}{\widehat{\bvec}}\) \(\newcommand{\bperp}{\bvec^\perp}\) \(\newcommand{\xhat}{\widehat{\xvec}}\) \(\newcommand{\vhat}{\widehat{\vvec}}\) \(\newcommand{\uhat}{\widehat{\uvec}}\) \(\newcommand{\what}{\widehat{\wvec}}\) \(\newcommand{\Sighat}{\widehat{\Sigma}}\) \(\newcommand{\lt}{<}\) \(\newcommand{\gt}{>}\) \(\newcommand{\amp}{&}\) \(\definecolor{fillinmathshade}{gray}{0.9}\)

    SAFETY PRECAUTIONS
    • Always wear chemical splash goggles and a lab coat in the laboratory.
    • You will be using an open Bunsen burner flame. Keep all flammable materials, paper, and hair away from the heat source.
    • Heated glassware remains hot for an extended period and can cause severe burns. Allow the test tube and apparatus to cool completely before touching.
    • Ensure all stopper connections are tight to prevent hot gas or pressure build-up leaks.

    EQUIPMENT AND CHEMICALS NEEDED

    Table \(\PageIndex{1}\): Materials List
    Equipment & Hardware Chemicals & Supplies
    Ring stand and utility clamp Bunsen burner & striker
    Large hard-glass test tube Pinch clamp & rubber tubing
    1-hole rubber stopper for test tube 400-mL beaker
    Glass tubing assemblies (bent glass tubes) 250-mL graduated cylinder
    500-mL Florence flask (or side-arm vacuum flask) Thermometer or temperature probe
    2-hole stopper for Florence flask Laboratory barometer
    Large rubber bulb or pipet pump Sodium bicarbonate (NaHCO3)

    EXPERIMENTAL PROCEDURE

    Part A: Assemble the Apparatus

    Goal: Establish a continuous, leak-free water siphon between the flask and the beaker.

    1. Assemble the gas displacement apparatus as shown in Figure \(\PageIndex{1}\).
      clipboard_ec1a69c29d3cf3c9d14d68e817fe3dd86.png
      Figure \(\PageIndex{1}\): Experimental apparatus setup.
    2. Fill the flask almost completely to the top with water and open the pinch clamp on the delivery tubing.
    3. Remove the rubber stopper from the empty test tube.
      clipboard_e16e6a56b72323fc077020390005a8988.png
      Figure \(\PageIndex{2}\): Siphon Setup.
    4. Using a large pipet pump, gently apply air pressure through the test tube stopper until the delivery hose is filled with water and flows into the beaker, creating a continuous siphon.
    5. Reinsert the stopper into the test tube while water is flowing. If the system is airtight, water flow will cease immediately. If water continues to flow, a leak is present; press all stoppers firmly. Ask your instructor if leaks persist.
    6. Close the pinch clamp on the rubber hose while it remains filled with water. Do not drain the hose.
    7. Remove the stopper from the test tube.
     

    Part B: Prepare the Sample and Flask

    Goal: Prepare the chemical sample and initialize the water level in the flask.

    1. Ensure the large test tube is completely clean and dry inside.
    2. Accurately weigh approximately 1.20 g of sodium bicarbonate on an analytical balance. Record the exact mass in the Data Table. Transfer the solid into the dry test tube. Do not attach the test tube stopper yet.
    3. Fill the 400-mL beaker about half full with water.
    4. Refill the flask: Open the pinch clamp and raise the beaker above the flask level so water siphons back in. Fill the flask until the water level reaches about 1 cm below the internal glass tubing.
    5. Close the pinch clamp while keeping the hose submerged.

    Part C: Equalize Initial System Pressure

    Goal: Ensure initial internal system pressure matches room atmospheric pressure (Patm).

    Illustration of a liquid transfer process using two flasks and connecting tubes, showing liquid moving from one flask to another.
    Figure \(\PageIndex{3}\): Pressure Equalization Procedure.
    1. Seal the System: Firmly press the rubber stopper into the test tube containing the sample.
    2. Open the Line: Open the pinch clamp.
    3. Leveling: Manually raise or lower the beaker until the water level (meniscus) in the beaker is at the same height as the water level in the flask (Figure \(\PageIndex{2}\)). When levels match, internal pressure equals atmospheric pressure.
    4. Lock Pressure: Holding the beaker steady at this height, close the pinch clamp.

    Part D: Final Setup for Gas Collection

    Goal: Prepare the beaker for water collection without breaking the liquid siphon.

    1. Empty the Beaker: Pour out the water from the beaker. Do not dry the inside; residual droplets will not affect measurements. Crucial: Keep the rubber hose filled with water.
    2. Position Hose: Place the empty beaker back on the lab bench and position the end of the rubber hose deep inside the beaker.
    3. Open System: Open the pinch clamp. A small amount of water may flow into the beaker or flask until equilibrium is reached; do not empty the beaker again.

    Part E: Decompose Sodium Bicarbonate

    Goal: Thermally decompose the sample to generate carbon dioxide gas.

    1. Light the Bunsen burner. Gently heat the test tube containing the NaHCO3 by moving the flame back and forth along the tube. After 1 minute of gentle heating, apply direct heat to the sample.
    2. Observe carbon dioxide evolution as displaced water flows into the beaker. Continue strong heating until gas evolution ceases completely.
    3. Remove the Bunsen burner flame and allow the entire apparatus to cool to room temperature (15–20 minutes).

    Part F: Equalize Final System Pressure

    Goal: Equalize final pressure to ensure collected volume reflects gas produced at atmospheric pressure.

    1. Cooling Check: Verify the test tube has cooled completely to room temperature. Equalizing while gas is warm will introduce significant volume error upon cooling.
    2. Final Leveling: Raise or lower the beaker until the water level in the beaker matches the water level in the flask exactly.
    3. Final Seal: While keeping the water levels aligned, close the pinch clamp to trap the exact volume of displaced water at atmospheric pressure. At this point: Ptotal = PCO2 + PH2O = Patm.
    4. Remove the rubber hose from the beaker.

    Part G: Measure Displaced Water and Conditions

    Goal: Measure displaced water volume, temperature, and atmospheric pressure.

    1. Measure the volume of water collected in the beaker using a 250-mL graduated cylinder. Record this volume to the nearest 0.5 mL.
    2. Measure and record the temperature of the water in the beaker. This corresponds to the gas temperature (Tlab) used to look up water vapor pressure.
    3. Read and record the laboratory barometric pressure (Patm).

    Part H: Repeat for Trial 2

    1. Clean the test tube, dry it thoroughly, and repeat the complete procedure (Parts A–G) with a second sample of sodium bicarbonate.
    CHEMICAL DISPOSAL
    • Dispose of solid sodium carbonate residue from the test tube in the designated SOLID CHEMICAL WASTE container.
    • Pour excess water down the laboratory drain. Clean all glassware before returning it.

    This page titled 9.1: Experimental Determination of the Ideal Gas Constant - Experiment was last modified on Thu, 05 Nov 2026 20:44:01 GMT and is shared under a CC BY 4.0 license and was authored, remixed, and/or curated by Vincent Hradil and Saadia Khan.