6.1: Determination of Empirical Formula - Experiment
- Page ID
- 547462
\( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)
\( \newcommand{\dsum}{\displaystyle\sum\limits} \)
\( \newcommand{\dint}{\displaystyle\int\limits} \)
\( \newcommand{\dlim}{\displaystyle\lim\limits} \)
\( \newcommand{\id}{\mathrm{id}}\) \( \newcommand{\Span}{\mathrm{span}}\)
( \newcommand{\kernel}{\mathrm{null}\,}\) \( \newcommand{\range}{\mathrm{range}\,}\)
\( \newcommand{\RealPart}{\mathrm{Re}}\) \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)
\( \newcommand{\Argument}{\mathrm{Arg}}\) \( \newcommand{\norm}[1]{\| #1 \|}\)
\( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)
\( \newcommand{\Span}{\mathrm{span}}\)
\( \newcommand{\id}{\mathrm{id}}\)
\( \newcommand{\Span}{\mathrm{span}}\)
\( \newcommand{\kernel}{\mathrm{null}\,}\)
\( \newcommand{\range}{\mathrm{range}\,}\)
\( \newcommand{\RealPart}{\mathrm{Re}}\)
\( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)
\( \newcommand{\Argument}{\mathrm{Arg}}\)
\( \newcommand{\norm}[1]{\| #1 \|}\)
\( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)
\( \newcommand{\Span}{\mathrm{span}}\) \( \newcommand{\AA}{\unicode[.8,0]{x212B}}\)
\( \newcommand{\vectorA}[1]{\vec{#1}} % arrow\)
\( \newcommand{\vectorAt}[1]{\vec{\text{#1}}} % arrow\)
\( \newcommand{\vectorB}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\( \newcommand{\vectorC}[1]{\textbf{#1}} \)
\( \newcommand{\vectorD}[1]{\overrightarrow{#1}} \)
\( \newcommand{\vectorDt}[1]{\overrightarrow{\text{#1}}} \)
\( \newcommand{\vectE}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash{\mathbf {#1}}}} \)
\( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)
\(\newcommand{\longvect}{\overrightarrow}\)
\( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)
\(\newcommand{\ket}[1]{\left| #1 \right>}\)
\(\newcommand{\bra}[1]{\left< #1 \right|}\)
\(\newcommand{\braket}[2]{\left< #1 \vphantom{#2} \right| \left. #2 \vphantom{#1} \right>}\)
\(\newcommand{\braopket}[3]{\left< #1 \vphantom{#2}\vphantom{#3} \right| #2 \vphantom{#1}\vphantom{#3} \left| #3 \vphantom{#1}\vphantom{#2} \right>}\)
\(\newcommand{\qmvec}[1]{\mathbf{\vec{#1}}}\)
\(\newcommand{\op}[1]{\hat{\mathbf{#1}}}\)
\(\newcommand{\expect}[1]{\langle #1 \rangle}\)
\(\newcommand{\dfn}[1]{\emph{\textbf{#1}}}\)
\(\newcommand{\avec}{\mathbf a}\) \(\newcommand{\bvec}{\mathbf b}\) \(\newcommand{\cvec}{\mathbf c}\) \(\newcommand{\dvec}{\mathbf d}\) \(\newcommand{\dtil}{\widetilde{\mathbf d}}\) \(\newcommand{\evec}{\mathbf e}\) \(\newcommand{\fvec}{\mathbf f}\) \(\newcommand{\nvec}{\mathbf n}\) \(\newcommand{\pvec}{\mathbf p}\) \(\newcommand{\qvec}{\mathbf q}\) \(\newcommand{\svec}{\mathbf s}\) \(\newcommand{\tvec}{\mathbf t}\) \(\newcommand{\uvec}{\mathbf u}\) \(\newcommand{\vvec}{\mathbf v}\) \(\newcommand{\wvec}{\mathbf w}\) \(\newcommand{\xvec}{\mathbf x}\) \(\newcommand{\yvec}{\mathbf y}\) \(\newcommand{\zvec}{\mathbf z}\) \(\newcommand{\rvec}{\mathbf r}\) \(\newcommand{\mvec}{\mathbf m}\) \(\newcommand{\zerovec}{\mathbf 0}\) \(\newcommand{\onevec}{\mathbf 1}\) \(\newcommand{\real}{\mathbb R}\) \(\newcommand{\twovec}[2]{\left[\begin{array}{r}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\ctwovec}[2]{\left[\begin{array}{c}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\threevec}[3]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\cthreevec}[3]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\fourvec}[4]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\cfourvec}[4]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\fivevec}[5]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\cfivevec}[5]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\mattwo}[4]{\left[\begin{array}{rr}#1 \amp #2 \\ #3 \amp #4 \\ \end{array}\right]}\) \(\newcommand{\laspan}[1]{\text{Span}\{#1\}}\) \(\newcommand{\bcal}{\cal B}\) \(\newcommand{\ccal}{\cal C}\) \(\newcommand{\scal}{\cal S}\) \(\newcommand{\wcal}{\cal W}\) \(\newcommand{\ecal}{\cal E}\) \(\newcommand{\coords}[2]{\left\{#1\right\}_{#2}}\) \(\newcommand{\gray}[1]{\color{gray}{#1}}\) \(\newcommand{\lgray}[1]{\color{lightgray}{#1}}\) \(\newcommand{\rank}{\operatorname{rank}}\) \(\newcommand{\row}{\text{Row}}\) \(\newcommand{\col}{\text{Col}}\) \(\renewcommand{\row}{\text{Row}}\) \(\newcommand{\nul}{\text{Nul}}\) \(\newcommand{\var}{\text{Var}}\) \(\newcommand{\corr}{\text{corr}}\) \(\newcommand{\len}[1]{\left|#1\right|}\) \(\newcommand{\bbar}{\overline{\bvec}}\) \(\newcommand{\bhat}{\widehat{\bvec}}\) \(\newcommand{\bperp}{\bvec^\perp}\) \(\newcommand{\xhat}{\widehat{\xvec}}\) \(\newcommand{\vhat}{\widehat{\vvec}}\) \(\newcommand{\uhat}{\widehat{\uvec}}\) \(\newcommand{\what}{\widehat{\wvec}}\) \(\newcommand{\Sighat}{\widehat{\Sigma}}\) \(\newcommand{\lt}{<}\) \(\newcommand{\gt}{>}\) \(\newcommand{\amp}{&}\) \(\definecolor{fillinmathshade}{gray}{0.9}\)
- Always wear chemical splash goggles and a lab coat in the laboratory.
- Hydrochloric acid (HCl) is corrosive and causes severe skin and eye burns. Handle with extreme care. If contact occurs, flush immediately with water and notify your instructor.
- The single-displacement reaction between aluminum wire and acid generates flammable hydrogen gas (H2). Keep all open flames away from the reaction beaker during Part B.
- Use crucible tongs when handling heated crucibles. Allow heated equipment to cool completely on a wire gauze before weighing.
EQUIPMENT AND CHEMICALS NEEDED
| Glassware & Hardware | Heating & Filtration | Chemicals & Reagents |
|---|---|---|
| 50-mL beaker & watch glass | Crucible with lid & crucible tongs | Copper chloride hydrate |
| Glass stirring rod | Ring stand, iron ring, & clay triangle | Aluminum wire (~0.25 g) |
| Electronic balance (±0.001 g) | Bunsen burner & hot plate | 6 M HCl(aq) solution |
| Büchner funnel, filter flask, & trap flask | 95% Ethanol | |
| Filter paper & vacuum hose | Deionized water |
EXPERIMENTAL PROCEDURE
Part A: Determine the Mass of Water by Dehydration
- Measure and record the mass of a clean, dry crucible with its lid in the data table.
- Add approximately 1.00 g of copper chloride hydrate to the crucible. Measure and record the combined mass of the crucible, lid, and hydrate sample.
- Set up a Bunsen burner, ring stand, iron ring, and clay triangle as shown in Figure \(\PageIndex{1}\). Place the crucible containing the sample onto the clay triangle. DO NOT cover the crucible. Begin heating gently with a small burner flame.
- CRITICAL: Do not overheat the sample, or the copper chloride salt will decompose into black copper(II) oxide. Move the burner base back and forth continuously to distribute heat evenly.
- Continue gentle heating until the green-blue crystals turn completely brown, signaling complete dehydration. Heat gently for an additional 2 minutes after the color change is complete.
- Turn off the Bunsen burner and cover the crucible with its lid to prevent atmospheric moisture rehydration during cooling. Cool to room temperature for 15 minutes. Inspect the sample; if any green color remains, reheat gently.
- Accurately measure and record the mass of the cooled crucible, lid, and anhydrous copper chloride.
Part B: Determine the Mass of Copper by Displacement
- Transfer the brown anhydrous copper chloride into a 50-mL beaker. Rinse the crucible with two 5-mL portions of deionized water, adding the washings to the beaker. Swirl the beaker to dissolve the salt completely, producing a clear green solution.
- Obtain approximately 0.25 g of aluminum wire. Form the wire into a loose coil and submerge it completely in the copper solution.
- Allow the single-displacement reaction to proceed for 25–30 minutes until the green solution turns completely colorless, indicating that all copper ions have been reduced to reddish-brown elemental copper metal.
- Add 5 drops of 6 M HCl(aq) to dissolve any insoluble aluminum hydroxide side-products and unreacted aluminum residue.
- Use a stirring rod to scrape copper metal off the aluminum wire. Rinse the wire with deionized water into the beaker, then remove the cleaned aluminum wire.
- Set up a vacuum filtration apparatus consisting of a Büchner funnel, rubber adapter, filter flask, safety trap flask, and vacuum hose (Figure \(\PageIndex{2}\)).
Figure \(\PageIndex{2}\): Vacuum filtration trap assembly. - Weigh a piece of dry filter paper and record its mass. Place the paper in the Büchner funnel and seat it with a few drops of deionized water.
- Turn on the vacuum suction and quantitatively transfer the copper metal onto the filter paper. Wash the copper thoroughly with deionized water.
- Turn off the vacuum and pour 10 mL of 95% ethanol over the copper residue to displace water. Wait 1 minute, then reapply vacuum suction for 5 minutes to air-dry the solid.
- Carefully transfer the filter paper with recovered copper onto a watch glass and dry on a low hot plate setting.
- Once cooled, measure and record the combined mass of the filter paper and dry copper metal.
- Dispose of the liquid filtrate into the designated NON-HALOGENATED ORGANIC WASTE container.
- Place unreacted aluminum wire and dry recovered copper powder into the designated SOLID METAL WASTE container.
- Clean all glassware and return equipment to its designated station.


