Skip to main content
Chemistry LibreTexts

5.2: Week 1 - Water

  • Page ID
    409180
  • ​

    ​

    \( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)

    \( \newcommand{\dsum}{\displaystyle\sum\limits} \)

    \( \newcommand{\dint}{\displaystyle\int\limits} \)

    \( \newcommand{\dlim}{\displaystyle\lim\limits} \)

    \( \newcommand{\id}{\mathrm{id}}\) \( \newcommand{\Span}{\mathrm{span}}\)

    ( \newcommand{\kernel}{\mathrm{null}\,}\) \( \newcommand{\range}{\mathrm{range}\,}\)

    \( \newcommand{\RealPart}{\mathrm{Re}}\) \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)

    \( \newcommand{\Argument}{\mathrm{Arg}}\) \( \newcommand{\norm}[1]{\| #1 \|}\)

    \( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)

    \( \newcommand{\Span}{\mathrm{span}}\)

    \( \newcommand{\id}{\mathrm{id}}\)

    \( \newcommand{\Span}{\mathrm{span}}\)

    \( \newcommand{\kernel}{\mathrm{null}\,}\)

    \( \newcommand{\range}{\mathrm{range}\,}\)

    \( \newcommand{\RealPart}{\mathrm{Re}}\)

    \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)

    \( \newcommand{\Argument}{\mathrm{Arg}}\)

    \( \newcommand{\norm}[1]{\| #1 \|}\)

    \( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)

    \( \newcommand{\Span}{\mathrm{span}}\) \( \newcommand{\AA}{\unicode[.8,0]{x212B}}\)

    \( \newcommand{\vectorA}[1]{\vec{#1}}      % arrow\)

    \( \newcommand{\vectorAt}[1]{\vec{\text{#1}}}      % arrow\)

    \( \newcommand{\vectorB}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \( \newcommand{\vectorC}[1]{\textbf{#1}} \)

    \( \newcommand{\vectorD}[1]{\overrightarrow{#1}} \)

    \( \newcommand{\vectorDt}[1]{\overrightarrow{\text{#1}}} \)

    \( \newcommand{\vectE}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash{\mathbf {#1}}}} \)

    \( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \(\newcommand{\longvect}{\overrightarrow}\)

    \( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)

    \(\newcommand{\ket}[1]{\left| #1 \right>}\)
    \(\newcommand{\bra}[1]{\left< #1 \right|}\)
    \(\newcommand{\braket}[2]{\left< #1 \vphantom{#2} \right| \left. #2 \vphantom{#1} \right>}\)
    \(\newcommand{\braopket}[3]{\left< #1 \vphantom{#2}\vphantom{#3} \right| #2 \vphantom{#1}\vphantom{#3} \left| #3 \vphantom{#1}\vphantom{#2} \right>}\)
    \(\newcommand{\qmvec}[1]{\mathbf{\vec{#1}}}\)
    \(\newcommand{\op}[1]{\hat{\mathbf{#1}}}\)
    \(\newcommand{\expect}[1]{\langle #1 \rangle}\)
    \(\newcommand{\dfn}[1]{\emph{\textbf{#1}}}\)

    \(\newcommand{\avec}{\mathbf a}\) \(\newcommand{\bvec}{\mathbf b}\) \(\newcommand{\cvec}{\mathbf c}\) \(\newcommand{\dvec}{\mathbf d}\) \(\newcommand{\dtil}{\widetilde{\mathbf d}}\) \(\newcommand{\evec}{\mathbf e}\) \(\newcommand{\fvec}{\mathbf f}\) \(\newcommand{\nvec}{\mathbf n}\) \(\newcommand{\pvec}{\mathbf p}\) \(\newcommand{\qvec}{\mathbf q}\) \(\newcommand{\svec}{\mathbf s}\) \(\newcommand{\tvec}{\mathbf t}\) \(\newcommand{\uvec}{\mathbf u}\) \(\newcommand{\vvec}{\mathbf v}\) \(\newcommand{\wvec}{\mathbf w}\) \(\newcommand{\xvec}{\mathbf x}\) \(\newcommand{\yvec}{\mathbf y}\) \(\newcommand{\zvec}{\mathbf z}\) \(\newcommand{\rvec}{\mathbf r}\) \(\newcommand{\mvec}{\mathbf m}\) \(\newcommand{\zerovec}{\mathbf 0}\) \(\newcommand{\onevec}{\mathbf 1}\) \(\newcommand{\real}{\mathbb R}\) \(\newcommand{\twovec}[2]{\left[\begin{array}{r}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\ctwovec}[2]{\left[\begin{array}{c}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\threevec}[3]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\cthreevec}[3]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\fourvec}[4]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\cfourvec}[4]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\fivevec}[5]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\cfivevec}[5]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\mattwo}[4]{\left[\begin{array}{rr}#1 \amp #2 \\ #3 \amp #4 \\ \end{array}\right]}\) \(\newcommand{\laspan}[1]{\text{Span}\{#1\}}\) \(\newcommand{\bcal}{\cal B}\) \(\newcommand{\ccal}{\cal C}\) \(\newcommand{\scal}{\cal S}\) \(\newcommand{\wcal}{\cal W}\) \(\newcommand{\ecal}{\cal E}\) \(\newcommand{\coords}[2]{\left\{#1\right\}_{#2}}\) \(\newcommand{\gray}[1]{\color{gray}{#1}}\) \(\newcommand{\lgray}[1]{\color{lightgray}{#1}}\) \(\newcommand{\rank}{\operatorname{rank}}\) \(\newcommand{\row}{\text{Row}}\) \(\newcommand{\col}{\text{Col}}\) \(\renewcommand{\row}{\text{Row}}\) \(\newcommand{\nul}{\text{Nul}}\) \(\newcommand{\var}{\text{Var}}\) \(\newcommand{\corr}{\text{corr}}\) \(\newcommand{\len}[1]{\left|#1\right|}\) \(\newcommand{\bbar}{\overline{\bvec}}\) \(\newcommand{\bhat}{\widehat{\bvec}}\) \(\newcommand{\bperp}{\bvec^\perp}\) \(\newcommand{\xhat}{\widehat{\xvec}}\) \(\newcommand{\vhat}{\widehat{\vvec}}\) \(\newcommand{\uhat}{\widehat{\uvec}}\) \(\newcommand{\what}{\widehat{\wvec}}\) \(\newcommand{\Sighat}{\widehat{\Sigma}}\) \(\newcommand{\lt}{<}\) \(\newcommand{\gt}{>}\) \(\newcommand{\amp}{&}\) \(\definecolor{fillinmathshade}{gray}{0.9}\)

    Pre-lab Assignment:

    ๐Ÿ“… Due: This pre-lab assignment is due prior to the Week 1 Dry Lab meeting.

    ๐ŸŽฏ Purpose:  Collect background information that can support the introduction section of your report, and prepare to make team decisions about Pb calibration and targets for qualitative analysis. You’ll read, calculate, and then propose a plan you can defend to your group. 

    Pre-Lab Tasks

    Read (and add references to Zotero)

    Pre-Lab Questions
    1. According to the EPA:
      • What is the safe level of Pb in drinking water?
      • What is the EPA action level for Pb, and how does it shape your expectations for this analysis?
    2. Given the EPA action level, what hypotheses do you form about our campus’s water, and how will these hypotheses guide your calibration strategy?
    3. Design a strategy for preparing the tainted water sample so that it will have 25 ppb Pb. Show your calculations and justify why this concentration is appropriate for the ICP-OES method. 
    4. Given the choice between external calibration and standard additions, what factors should your team consider in deciding which to use for this experiment? Describe how matrix effects might influence your decision.
    5. Based on your predictions about the water samples and possible matrix effects, which calibration method should your team adopt? Justify your choice by comparing the advantages and limitations of each method in this context. Be prepared to defend your proposal to your team in Dry Lab.
    6. If your team adopts the calibration method you proposed, what specific standards will you need to prepare? Show one example calculation and explain why these standards are appropriate for detecting ~25 ppb Pb with ICP-OES.
    7. Suppose one team member argues for external calibration because it is simpler and faster, while another argues for standard additions because of possible matrix effects. How would you lead your team to consensus on which method to use?
    Water Sample

    ๐Ÿ“… Due: Collect 1.0 L of water sample prior to the Week 1 WET Lab meeting. Bottles are available for sample collection; they are in the cabinets underneath the ICP-OES in 1112 FFSC. 

    Each group member should collect one unique water sample.  You may take water from unique locations on campus or from the same locations at a different time of day. (See where other groups have collected samples on google maps). Each sample should be approximately 1 L of water, and collected using a clean metal-free container. The water should be chosen from a drinking water source on Duke's campus.*

    Caution

    If you are using your own container to collect drinking water for analysis, it must be rinsed with nitric acid to remove residual metals from the inside of the container. Be sure to use a metal-free sample collection vessel.

    *If you would prefer to analyze water sources from your home or another place of interest, you are welcome to do so. We can perform qualitative analysis for almost any element - feel free to follow your interests! If you would like to do qualitative analysis on additional samples, they should be collected in smaller 50 mL tubes or in your own containers.  You could choose to collect water from a filtered bottle filling station - but some contaminants may be removed already by the filling station filter.


    ๐Ÿ‘ฅ Dry-Lab Group Discussion:

    In this discussion, you will practice making scientific decisions as a team. Instead of simply following a procedure, you will weigh evidence, anticipate challenges such as matrix effects, and reach consensus on an analysis plan. By the end of this session, your group will have chosen a calibration strategy and identified additional elements for qualitative analysis. These decisions will prepare you to enter Wet Lab with a clear plan, so that your calibration standards and water samples can be prepared efficiently and consistently. This work also develops transferable skills in collaborative problem-solving, justifying methodological choices, and documenting group decisions—skills that are essential for authentic scientific research.

    ๐ŸŽฏ Goals: By the end of today’s discussion, your team will:

    • Choose one calibration strategy (all members use the same).
    • Finalize a Pb calibration set (levels, glassware plan, who prepares what).
    • Select ≥4 qualitative targets beyond Pb and record your rationale (how they help interpret filter performance and matrix effects).

    Instructions:

    • Begin the session by grouping up and assigning roles (scribe, reporter, spokesperson, time keeper)
      • The Time Keeper will start a timer and encourage group consensus.
      • The Scribe will record the group work.
      • The Spokesperson will summarize your group’s decisions to the class in 2 minutes at the end of discussion. 
      • The reporter will submit the group record at the end of class.
    • Work on the discussion questions together in your group for ~25 minutes.
    • Report out
      • What are the elements chosen for qualitative analysis?
      • Describe your calibration strategy and justify this choice.
    • As a group, make a detailed plan for creating calibration standards so that you can begin solution preparations immediately at the start of wet lab.
    Group Discussion Prompts
    1. Elements for Qualitative Analysis
      • Each group member brings at least two candidate elements from the pre-lab. As a group, discuss:
        • Which elements are most likely to be present in drinking water at detectable levels?
        • Decision: Select at least three elements for qualitative analysis (beyond Pb).
        • Action: Record your group’s list with a short justification for each.
    2. In this module, we are addressing the question "How well does a water filter work?". Considering this, explain why we are creating a tainted water sample instead of just working with the plain drinking water sample.
    3. Calibration Strategy for Quantitative Analysis of Pb
      • Share your individual pre-lab calibration proposals. What evidence or reasoning did each of you use?
      • If you use external calibration, how can you validate your calibration and determine whether there are matrix effects?
      • In the context of this project, what are the pro's and con's of calibrating with the method of standard additions instead of external calibration?
      • Decision Point: Which calibration method will your group use?
      • Action: Write down your choice and the main reasons (bullet points are fine).Planning Calibration Standards & Samples
    4. Protocol for Standard Preparation: Review your pre-lab calculations for tainting and standard preparation.
      • Is the range of standards appropriate for measuring ~25 ppb Pb? Explain your reasoning.
      • Decision Point: Finalize the set of calibration standards that your group will prepare in Wet Lab. Your entire group should agree on the range and concentrations of each standard. Each group member will prepare their own calibration replicate(s).
      • Action: Write down the agreed concentrations and required glassware/pipettes. Create a group protocol for preparing the standards.
    5. In the context of analyzing drinking water with ICP-OES, what kinds of questions can we answer using qualitative analysis, and what questions require quantitative analysis? Give at least one example for each from your group’s water project.
    6. How might the choices your group made today appear in the Introduction or Methods section of your manuscript? Draft one sentence that could appear in your Methods section to describe your calibration strategy.

    ๐Ÿงช Wet-Lab Work:

    ๐ŸŽฏ Goals for Wet Lab: By the end of Week 1 Wet Lab, aim to accomplish:

    • Prepare three samples for QUAL analysis (~10-15 mL each).
    • Build a group method file for QUAL analysis.
    • Run all samples using the QUAL method and harvest data in a form that is useful for your report.
    • Make progress toward calibration of the instrument for QUANT analysis.

    Agenda for Wet Lab

    1. Prepare containers (remove trace metals)
    2. Prepare samples
      • source (untainted) samples
      • tainted water samples
      • filtered water samples
    3. Collect qualitative data on the samples.
    4. Prepare calibration standards and spiked recovery samples
    5. Collect calibration and sample data to determine the Pb concentration (if time allows)
      • Create a calibration curve
      • Use your calibration to determine the amount of Pb in your water samples.
      • Validate your method by performing a spiked recovery if applicable - If you cannot validate your method, revise your strategy and try again.
    6. Store all samples in sealed containers and clean up.

    Instructions for Completing Wet Lab Work

    1. Prepare your containers

    Remove trace metals from any glassware or reusable sample containers!

    All sample containers and glassware must be rinsed well with dilute nitric acid (0.1 M) to dissolve and remove any trace metal ions that are bound to the interior surface of the container. Expose the interior of the container to 0.1 M nitric acid (\(\ce{HNO3}\)) in deionized water for 10 minutes, then rinse with deionized water.

    2. Sample Preparation

    Each group member will prepare three types of samples for this analysis using their unique source water. Prepare each sample for analysis by filling an autosampler tube about 4/5 full with the sample:

    1. Source water sample: This is the water directly from the source tap (aka "untainted water"). Rserve approximately 100 mL of your source water sample for direct analysis using the ICP-OES. In other words, save some and don't taint it or filter it so we can measure its "original" contents. Fill an autosampler tube with about 10-12 mL of this water for QUAL analysis.  You will use the remaining ~90 mL for your QUANT calibration standards or validation.
    2. Tainted water sample: We really hope, and expect, that you won't find much, if any, toxic metal in the water on our campus! So...to give you some Pb to work with, you will use a certified element standard to contaminate 500 mL of water sample to a final concentration of 25.0 ppb Pb. This is your "tainted" water sample. After you prepare the tainted water solution, prepare a sample for analysis by putting about 10-12 mL in a labeled 15 mL tube. Reserve some of this tainted water for calibration or validation.
    3. Filtered water: You will use a Brita water filter cartridge to filter a portion of your tainted water and then measure the Pb concentration of the filtered water. 
      • Steps to prepare the filtered water:
        1. Start by rinsing the filter and pitcher with deionized water three times.
        2. Remove all water from the pitcher and gently shake the pitcher to remove excess water from the entire filter unit. 
        3. Prepare the filter: Filter a small portion of your tainted water three times, discard the filtered water each time into a waste container.
        4. Filter a fourth portion of the tainted water, and collect the filtrate into a clean container.  Collect enough filtered sample for the Qual analysis, as well as for calibration or validation.  Transfer 10-12 mL of the filtered water to an autosampler tube. This is the filtered water sample for analysis.

    Figure \(\PageIndex{1}\): Scheme for sample preparation (CC BY SA; Kathryn Haas)
    3. Qualitative Analysis of samples (what's in this water?)

    As a group, create an ICP-OES instrument method and analyze all of your group's samples (3 samples per person). Your qualitative analysis method should include Pb and all the elements that your team chose for analysis (from your Dry Lab decisions).

    Your Data Checklist

    To prepare for analysis and manuscript writing, be sure to export and save the following items to your own computer or cloud storage before you leave the lab:

    • For each element and each water source: Overlaid emission spectra of that element in the blank, in the source water, the tainted water, and the filtered water. (If there were two unique water sources and three elements, this would be six separate figure panels).
    • Export the emission peak values (the results table) for all samples and all elements, including the blank
    4. Prepare Calibration Standards

    The calibration method is up to you! Review the different methods of calibration (single vs multi-point, external calibration, standard addition) that you have or will learn about in the complimentary Analytical Chemistry Lecture Course. You should choose a method of multi-point calibration and plan how you will create the standard solutions necessary to calibrate the instrument. The goal is to accurately measure a solution of approximately 25 ppb Pb. Your group will be provided with the following materials:

    • Up to 250 mL of a certified Pb standard that contains \(1.000 \pm 0.002\) mg/L (ppm) Pb. 
    • deionized water
    • 0.1 M nitric acid in deionized water
    • any flasks and containers available in the lab
    • digital pipettes (for delivering volumes less than 1 mL, or odd volumes <5 mL for which volumetric pipets are unavailable) 
    • volumetric pipets (for most volumes > 1 mL)

    You will be given a certified Pb standard that you can use to create the standard solutions or spikes necessary to calibrate the method. You should use volumetric glassware and techniques as you've practiced earlier in this course. If you need to transfer a volume of <5 mL that does no correspond to a typical capacity of a volumetric pipet, a digital pipette can be used to transfer volumes between 10-5000 \(\mu L\). Take note of the errors associated with different types and sizes of pipet(te)s (see orientation module). Make sure that all the glassware is cleaned well to remove any trace contamination (see instructions above).

    5. Quantitiative Analysis of Pb (how much?)

    As a group, create an ICP-OES instrument method and analyze all of your group's calibration standards and samples. Your quantitative analysis method should include only Pb for elemental analysis and calibration.

    The analysis of all samples will take a while, and can be automated to run while you are away.  While these samples are running, work on harvesting qualitative data.


    ๐Ÿ“˜ Notebook

    Record detailed notes about your lab work in your notebook each time you are in lab. Also include the data analysis and responses to the reflection prompts*. Your notebook should be submitted on canvas prior to leaving Wet Lab each week - whatever state it is in at the end of lab is the state in which you should submit your work.  If you are unable to complete data analysis and the reflection prompt within the period, it should be completed before the next lab period, and submitted with your next notebook submission.

    Reflection Prompt \(\PageIndex{0}\) 

    We assume you haven't gotten a chance to fully collect or analyze calibration data at this point, so these questions are focused on qualitative data.

    1. Qualitative Analysis Results: What elements did you detect in your source water, tainted water, and filtered water? Which of these findings were expected based on your pre-lab predictions, and which were surprising?
    2. Matrix Effects and Calibration Choices: Based on your results, what evidence do you see of possible matrix effects? How would you evaluate whether your calibration strategy (external vs. standard additions) is an effective choice?
    3. Filter Effectiveness: How did filtration affect the signals for Pb and your team’s additional elements? Did the filter perform as you expected? What evidence supports your conclusion?
    4. Reproducibility: How reproducible are your results based on replicate measurements or repeated scans? If variation differs by signal intensity, what might explain that trend?
    5. Data Presentation & Communication: Include one overlaid spectrum (at least one analyte across source/tainted/filtered).
      • Provide a short figure caption that communicates what the spectrum shows and why it matters.
      • Write 2–3 sentences explaining how you might present these results in the Results section of a scientific manuscript.

    ​​​​​​


    This page titled 5.2: Week 1 - Water was last modified on Thu, 02 Oct 2025 15:35:09 GMT and is shared under a CC BY-NC-SA 4.0 license and was authored, remixed, and/or curated by Kathryn Haas.

     