Skip to main content
Chemistry LibreTexts

4.6: TA Notes

  • Page ID
    460987
  • ​

    ​

    \( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)

    \( \newcommand{\dsum}{\displaystyle\sum\limits} \)

    \( \newcommand{\dint}{\displaystyle\int\limits} \)

    \( \newcommand{\dlim}{\displaystyle\lim\limits} \)

    \( \newcommand{\id}{\mathrm{id}}\) \( \newcommand{\Span}{\mathrm{span}}\)

    ( \newcommand{\kernel}{\mathrm{null}\,}\) \( \newcommand{\range}{\mathrm{range}\,}\)

    \( \newcommand{\RealPart}{\mathrm{Re}}\) \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)

    \( \newcommand{\Argument}{\mathrm{Arg}}\) \( \newcommand{\norm}[1]{\| #1 \|}\)

    \( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)

    \( \newcommand{\Span}{\mathrm{span}}\)

    \( \newcommand{\id}{\mathrm{id}}\)

    \( \newcommand{\Span}{\mathrm{span}}\)

    \( \newcommand{\kernel}{\mathrm{null}\,}\)

    \( \newcommand{\range}{\mathrm{range}\,}\)

    \( \newcommand{\RealPart}{\mathrm{Re}}\)

    \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)

    \( \newcommand{\Argument}{\mathrm{Arg}}\)

    \( \newcommand{\norm}[1]{\| #1 \|}\)

    \( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)

    \( \newcommand{\Span}{\mathrm{span}}\) \( \newcommand{\AA}{\unicode[.8,0]{x212B}}\)

    \( \newcommand{\vectorA}[1]{\vec{#1}}      % arrow\)

    \( \newcommand{\vectorAt}[1]{\vec{\text{#1}}}      % arrow\)

    \( \newcommand{\vectorB}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \( \newcommand{\vectorC}[1]{\textbf{#1}} \)

    \( \newcommand{\vectorD}[1]{\overrightarrow{#1}} \)

    \( \newcommand{\vectorDt}[1]{\overrightarrow{\text{#1}}} \)

    \( \newcommand{\vectE}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash{\mathbf {#1}}}} \)

    \( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \(\newcommand{\longvect}{\overrightarrow}\)

    \( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)

    \(\newcommand{\ket}[1]{\left| #1 \right>}\)
    \(\newcommand{\bra}[1]{\left< #1 \right|}\)
    \(\newcommand{\braket}[2]{\left< #1 \vphantom{#2} \right| \left. #2 \vphantom{#1} \right>}\)
    \(\newcommand{\braopket}[3]{\left< #1 \vphantom{#2}\vphantom{#3} \right| #2 \vphantom{#1}\vphantom{#3} \left| #3 \vphantom{#1}\vphantom{#2} \right>}\)
    \(\newcommand{\qmvec}[1]{\mathbf{\vec{#1}}}\)
    \(\newcommand{\op}[1]{\hat{\mathbf{#1}}}\)
    \(\newcommand{\expect}[1]{\langle #1 \rangle}\)
    \(\newcommand{\dfn}[1]{\emph{\textbf{#1}}}\)

    \(\newcommand{\avec}{\mathbf a}\) \(\newcommand{\bvec}{\mathbf b}\) \(\newcommand{\cvec}{\mathbf c}\) \(\newcommand{\dvec}{\mathbf d}\) \(\newcommand{\dtil}{\widetilde{\mathbf d}}\) \(\newcommand{\evec}{\mathbf e}\) \(\newcommand{\fvec}{\mathbf f}\) \(\newcommand{\nvec}{\mathbf n}\) \(\newcommand{\pvec}{\mathbf p}\) \(\newcommand{\qvec}{\mathbf q}\) \(\newcommand{\svec}{\mathbf s}\) \(\newcommand{\tvec}{\mathbf t}\) \(\newcommand{\uvec}{\mathbf u}\) \(\newcommand{\vvec}{\mathbf v}\) \(\newcommand{\wvec}{\mathbf w}\) \(\newcommand{\xvec}{\mathbf x}\) \(\newcommand{\yvec}{\mathbf y}\) \(\newcommand{\zvec}{\mathbf z}\) \(\newcommand{\rvec}{\mathbf r}\) \(\newcommand{\mvec}{\mathbf m}\) \(\newcommand{\zerovec}{\mathbf 0}\) \(\newcommand{\onevec}{\mathbf 1}\) \(\newcommand{\real}{\mathbb R}\) \(\newcommand{\twovec}[2]{\left[\begin{array}{r}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\ctwovec}[2]{\left[\begin{array}{c}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\threevec}[3]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\cthreevec}[3]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\fourvec}[4]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\cfourvec}[4]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\fivevec}[5]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\cfivevec}[5]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\mattwo}[4]{\left[\begin{array}{rr}#1 \amp #2 \\ #3 \amp #4 \\ \end{array}\right]}\) \(\newcommand{\laspan}[1]{\text{Span}\{#1\}}\) \(\newcommand{\bcal}{\cal B}\) \(\newcommand{\ccal}{\cal C}\) \(\newcommand{\scal}{\cal S}\) \(\newcommand{\wcal}{\cal W}\) \(\newcommand{\ecal}{\cal E}\) \(\newcommand{\coords}[2]{\left\{#1\right\}_{#2}}\) \(\newcommand{\gray}[1]{\color{gray}{#1}}\) \(\newcommand{\lgray}[1]{\color{lightgray}{#1}}\) \(\newcommand{\rank}{\operatorname{rank}}\) \(\newcommand{\row}{\text{Row}}\) \(\newcommand{\col}{\text{Col}}\) \(\renewcommand{\row}{\text{Row}}\) \(\newcommand{\nul}{\text{Nul}}\) \(\newcommand{\var}{\text{Var}}\) \(\newcommand{\corr}{\text{corr}}\) \(\newcommand{\len}[1]{\left|#1\right|}\) \(\newcommand{\bbar}{\overline{\bvec}}\) \(\newcommand{\bhat}{\widehat{\bvec}}\) \(\newcommand{\bperp}{\bvec^\perp}\) \(\newcommand{\xhat}{\widehat{\xvec}}\) \(\newcommand{\vhat}{\widehat{\vvec}}\) \(\newcommand{\uhat}{\widehat{\uvec}}\) \(\newcommand{\what}{\widehat{\wvec}}\) \(\newcommand{\Sighat}{\widehat{\Sigma}}\) \(\newcommand{\lt}{<}\) \(\newcommand{\gt}{>}\) \(\newcommand{\amp}{&}\) \(\definecolor{fillinmathshade}{gray}{0.9}\)

    This page is directed toward laboratory teaching assistants, but is deliberately left open for students to read.

    TA Notes

    After completion of this module students will be able to:

    1. Use analytical techniques to create a serial dilution starting from pure, solid material. (Use an analytical balance, volumetric glassware, and pipettes)
    2. Use a full-spectrum UV-vis to measure the absorbance of a series of solutions.
    3. Determine the best wavelength to monitor the absorbance of an analyte.
    4. Validate a series of standard solutions using a control.
    5. Explain the principles of liquid-liquid partitioning.
    6. Explain the effect of solvent polarity on retention times.
    7. Explain the effects of isocratic and gradient methods on retention times and peak shape.
    8. Interpret chromatographic data to identify components of a mixture and determine their concentration.

    Pre-Semester Preparations

    Do the following during the TA training and orientation week(s)

    1. Check that the materials listed below are available and sufficient for all students to use them. If they are running low, please create more or inform the instructor. 

      • Caffeine, 99%: There should be at least ~25 g of caffeine powder available. If not, please inform the lab director.

      • Volumetric Glassware: Be sure that there is sufficient glassware for four students to complete the experiment simultaneously. Please inspect the glassware for chips or obvious contamination. Clean or dispose of glassware as needed and inform the instructor if more glassware should be added to the lab space.

      • HPLC Autosampler vials: About 6 vials per student

      • Syringes and syringe-driven filters: One each per student

      • Access to UV-vis and at least two quartz cuvettes for each student (Glass cuvettes will not work! Students can take turns.)

    2. Complete instrument training with Dr. Haas.
    3. Perform the entire experiment as if you were a student.
    4. Write and submit a report as if you were a student.
    5. Practice grading your and your partner's report using the grading rubric.

    Pre-Lab Preparations

    When you are on TA duty, arrive at least 20-30 minutes early to prepare and ready the following materials for students.

    • Check to be sure that caffeine powder is in its place (notify the instructor if we should order more). 
    • Check to be sure there are cuvettes available for students to use. They should be quartz cuvettes, not glass. 
    • Remind students to sign into lab 
    • Check that the student's pre-lab is complete 
      • Check their proposed calibration points and ensure that the control solution is approximately in the middle of their range.
    • Tell students to gather their glassware as soon as they arrive and get set up on a bench space so that they can make solutions. 
    • They should clean their glassware prior to use. 
    • The Cary 100 UV-vis instruments should be turned on at the beginning of lab period. Let the students be involved in this. 
    • Check that all HPLC modules are powered on (please do not touch the buttons on the bottom components!). The degasser (top unit) is the only one that should possibly be turned off at the button on the instrument. 
    • Check solvent reservoirs and refill if they are less than half full.
    • Show students how to open the software and turn the instrument components on from the software.
    • Show students how to start a method running to equilibrate the column to the starting conditions of their first run. Be sure that the pressure is reasonable and the instrument is performing as expected. Otherwise, get help.

    Helping your students

    During the laboratory session, you are expected to be present and available for the entire 4.5 hours. Your job is to help students to complete the experiment safely and successfully, while upholding expectations and academic standards for the students. 

    Creating Standard Solutions and Analysis by UV-Vis

    In this first laboratory session, please provide explicit instruction on the following:

    • Weighing solid material: They can begin by weighing their caffeine when their glassware is clean. Please show students how to use the balances correctly and remind them that there is error associated with the measurement. (refer to P-chem materials…we assume that it is in the last digit of the reported number.) Show them how to quantitatively transfer their material into a volumetric flask, rinsing the weighing container into the flask with water. 
    • For using volumetric flasks: Remind them to use good technique. We can assume students know how to use these, but…..It takes a while to dissolve the solid material.  DON’T LET THEM MOVE ON TOO QUICKLY!  With powder in flask, fill it about 1/2 to 3/4 with solvent, swirl and sonicate as necessary to dissolve the solid before filling to the line. 

    Help students to analyze data immediately upon collection. They should validate their standard curve (UV-vis) using a control solution. The control solution is provided, and it should be within the concentration range of their calibration curve. If the control is outside their calibration range, a new control should be created. The students should treat the control as a sample in their calibration template, then compare their derived concentration to the known concentration. If the values are the same, then the curve is validated. If not, the students should re-create the standards using correct analytical technique. The students shold proceed to the HPLC module only after the calibration is validated.

    Encourage students to proceed to the next step and begin creating methods for the HPLC if they have validated their curve and there is additional time in the period.

    Analysis of Caffeine by HPLC

    Be available to answer questions and troubleshoot any issues as students build HPLC methods and sequence files. Please discuss the following with them:

    • General principles of reverse phase chromatography.
    • How we predict relative retention of molecules based on their structure and the type of chromatography. 
    • General expectations for isocratic vs gradient methods.
    • Selection of the appropriate wavelength for monitoring caffeine.

    During data collection, check to be sure the report is giving peak integrations. If not, please show the students how to manually integrate the peaks and harvest their data electronically.

    Remind students to use the control solution to validate their calibration. In this case, if the UV-vis calibration is valid, we expect the HPLC to also be validated. However, it this is not the case, please discuss with the instructor. If the UV-vis calibration was validated, we have confidence that the solutions were made correctly, and there must be another reason that the HPLC calibration has failed.

    Shut down/ clean up 

    15 minutes prior to the end of the period, students should stop lab work and clean up. They are to leave the room in clean condition prior to the end of the period (17:55).

    • Remind students when it is time to clean up.
    • Remind students to save their samples!
    • Turn off the UV-vis
    • Remind students that all glassware should be returned to the storage locations.
    • Any samples that are stored should be labeled clearly with the student's name and section.
    • Remind students to sign out with the time they leave and get your signature.
    • Check the TA checklist for additional items to be completed.

    This page titled 4.6: TA Notes was last modified on Tue, 17 Dec 2024 17:34:33 GMT and is shared under a CC BY-NC-SA 4.0 license and was authored, remixed, and/or curated by Kathryn Haas.

     

    • Was this article helpful?