6.2: Thin Layer Chromatography (TLC)

  • Page ID
    212590
  • \( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \) \( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)\(\newcommand{\id}{\mathrm{id}}\) \( \newcommand{\Span}{\mathrm{span}}\) \( \newcommand{\kernel}{\mathrm{null}\,}\) \( \newcommand{\range}{\mathrm{range}\,}\) \( \newcommand{\RealPart}{\mathrm{Re}}\) \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\) \( \newcommand{\Argument}{\mathrm{Arg}}\) \( \newcommand{\norm}[1]{\| #1 \|}\) \( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\) \( \newcommand{\Span}{\mathrm{span}}\) \(\newcommand{\id}{\mathrm{id}}\) \( \newcommand{\Span}{\mathrm{span}}\) \( \newcommand{\kernel}{\mathrm{null}\,}\) \( \newcommand{\range}{\mathrm{range}\,}\) \( \newcommand{\RealPart}{\mathrm{Re}}\) \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\) \( \newcommand{\Argument}{\mathrm{Arg}}\) \( \newcommand{\norm}[1]{\| #1 \|}\) \( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\) \( \newcommand{\Span}{\mathrm{span}}\)\(\newcommand{\AA}{\unicode[.8,0]{x212B}}\)

    In thin layer chromatography the solid phase (silica gel or alumina) is applied as a thin coating on a plastic sheet or glass slide, called a TLC plate (fig. 20.4, p. 783). Using a capillary tube, a solution of the sample is applied on the solid support as a spot, a technique known as spotting. When the sample dries it becomes adsorbed onto the solid support. This process can be repeated several times to produce a more concentrated spot.

    SPOTTING TECHNIQUE

    1. Throughout these operations, keep in mind that the coating on the TLC plate is very fragile and easily chips. Plates must be handled with care.

    2. Using a pencil, not ink, draw a horizontal line about 1 cm from the bottom of the TLC plate to mark the starting point of the sample for elution. Do not apply too much pressure, or you will break the coating. The sample spots are to be applied on this horizontal line.

    3. Dip the tip of a capillary micropipette in a solution of the sample to be analyzed. Capillary action will cause the liquid to rise up the pipette.

    4. Lightly touch the solid support with the tip of the micropipette as if using a fountain pen. A small amount of solution will transfer to the plate forming a spot. As with a real pen, the longer you leave the pipette in contact with the plate the bigger the spot. We don’t want big spots, therefore just “peck” the coating and withdraw the pipette.

    5. Wait until the spot dries before applying the next one, which should be done on exactly the same place. With most solutions, 3 or 4 applications of the same solution should suffice to produce a good spot. A spot that’s too dense or too big can cause problems during the separation.

    6. If you are applying several different samples on the same plate, make sure their spots do not touch each other. Adjacent spots must be separated by a minimum distance of 0.5 cm, or they’ll run into each other during the separation.

    7. Likewise, spots must not be too close to the edge of the plate, or they can run off the plate during separation. Again, spots should be separated from the edges by a minimum of 0.5 cm, except for the bottom of the plate, in which case they should be separated by a minimum of 1 cm. The reason is that the plate will be immersed in the eluting solvent to effect the separation, and the eluting solvent should not touch the spots when the separation begins.

    THE DEVELOPING CHAMBER

    While the spots are being applied and allowed to dry, prepare a developing chamber for the separation (that’s a fancy name for a beaker or jar that’s slightly taller than the TLC plate). Refer to fig. 20.5 on p. 784.

    To do this take a clear container and place a small amount of eluting solvent inside, just about enough to cover the bottom. You can also take a piece of filter paper whose diameter is about the height of the container and place it around the walls. Squirt some of the eluting solvent on the filter paper to make it wet so that it adheres to the walls better. This keeps the space inside the container saturated with solvent vapors to minimize loses by evaporation and improve the separation. Also have a lid or watch glass ready to cover the container during the separation.

    ELUTION TECHNIQUE

    Once the TLC plate has been spotted and ready to go, carefully place it inside the developing chamber, trying to avoid splashing. Remember, we don’t want the solvent to touch the spots before we start the separation. If it does, it will cause the spots to smear and they’ll become useless.

    The plate should be placed upright, slightly inclined against the wall of the container. The solvent should not touch the spots when the separation first begins, that’s why its level should be below the spots by at least 0.5 cm. Cover the container and wait for elution to proceed.

    By capillary action, the solvent will immediately start rising up the TLC plate. As soon as it comes into contact with the spots, it will cause the less polar components of the mixture to start moving. The more polar components will also move, but at a less noticeable rate. The following diagram illustrates the process.

    clipboard_ef9a3d13872905b621667bc71881ee639.png

    clipboard_ebd1229f6ff0c55281ad2d7ee6a201cf4.png

    PART A – Separating the components of a mixture using a given solvent.

    clipboard_e4c2d1da6b148512e344f6cf053c56374.png

    When the plate is first placed inside the developing chamber, its bottom should be as parallel as possible with the solvent level. If the plate enters the solvent at an angle, it will cause a slanted solvent front line which may result in poor separation and uneven alignment of the spots.

    When the solvent front is about 0.5 to 1 cm from reaching the top, it’s time to stop the elution. Do not allow the solvent front to reach the top of the plate. That may cause erroneous Rf values and may cause spots that are close together to run into each other. Take the plate out with tweezers and mark the solvent front line with a pencil as soon as possible. If you wait too long, it will fade and you will miss a crucial part of information needed to calculate the Rf values.

    If a poor separation is obtained with a certain solvent, the experiment needs to be repeated with a solvent of different polarity. As with crystallization, solvent mixtures can be used to achieve intermediate degrees of polarity. Low polarity solvents will cause the spots to move more slowly. High polarity solvents will do the opposite. Either extreme can cause poor separation. Only practice will enable you to gain a sense of how to reach a “happy medium.”

    PART B – Finding the solvent that provides the best separation.

    clipboard_eec4805ed34ea70ed8e0f9627d720ef9a.png

    VISUALIZATION TECHNIQUES

    After taking the TLC plate out of the developing chamber and marking the solvent front line, allow the plate to dry. Drying can be accelerated by placing the TLC plate on a lukewarm surface. Remember, the plate is made of plastic, if the plate is too hot the plastic will melt. Once the plate is dry, you need to be able to see the spots. Unless your sample is colored, this is not always possible with the naked eye. Visualization techniques are methods that enable you to see otherwise “invisible” spots. There are several methods available, but the two most commonly used in the organic lab are iodine staining, and use of a UV lamp.

    Iodine reacts with many organic substances to produce compounds which are brownish. Place the TLC plate inside an iodine chamber (again, a fancy name for a jar that contains a few iodine crystals). Close the jar, and within a few minutes spots will appear on the plate. This process can be accelerated by placing the chamber on a warm surface. Once you can see the spots, take the TLC plate out of the chamber with tweezers or wearing gloves (iodine is a toxic substance, and so are its vapors). Mark the spots with a pencil.

    Most commercial TLC plates contain not only the solid phase coating, but also a fluorescent substance that is sensitive to ultraviolet (UV) light. By shining UV light with a special lamp on the plate, the coating will appear greenish. If there are spots or other substances blocking the light, they will appear blackish. This will enable you to mark the places where the spots are with a pencil.

    Since iodine vapors are toxic, only the UV lamp will be used in the lab.

    CALCULATING Rf VALUES

    The scientific measure of the chromatographic separation in TLC is the Rf value, variously interpreted in different sources as retardation factor, ratio to the front, etc. (see p. 788). It is given by the expression

    \(R_{f} = \frac{\textrm{distance traveled by the spot}}{\textrm{distance traveled by the solvent front}}\)

    See fig. 20.8 on p. 788 for an example. Some spots are somewhat large, while others “tail.” Tailing tends to occur with ionic or highly polar substances that are reluctant to move because they bind too strongly to the solid phase. When this happens the center of mass of the spot is used to measure the distance traveled by the spot. The reaction with iodine as a visualization method is particularly good at revealing the densest part of the spot.

    clipboard_e8b1bc65641e28425ffb197929b3b4f24.png

    By definition, Rf values are always less than 1. An Rf value of 1 or too close to it means that the spot and the solvent front travel close together and is therefore unreliable. This happens when the eluting solvent is too polar for the sample. Another run must be made using a less polar solvent to improve the separation.

    Likewise, if the spot hardly moves and its traveled distance is nearly zero, there has probably been no chance for separation. This happens when the eluting solvent is not polar enough for the sample. Another run must be made using a more polar solvent to improve the separation.

    RELATIONSHIP BETWEEN Rf VALUE AND POLARITY OF THE SAMPLE

    It was mentioned before that the polarity of the sample and its rate of movement are inversely related. The more polar spot travels slower, and the less polar spot travels faster. Rf values, on the other hand, are directly related to the rate of movement. The fastest moving spot has the highest Rf value.

    Therefore Rf values and polarity are inversely related. The spot with the highest Rf value is the least polar (fastest moving), and the spot with the lowest Rf value is the most polar (slowest moving).

    USES OF Rf VALUES IN TLC

    Rf values are frequently used to compare a known and an unknown substance to determine if they are the same. As long as their spots are run simultaneously on the same plate, the argument can be made that if their Rf values are the same, and if the general appearance of the spots is the same, then they are the same compound.

    Rf values depend on:

    • The polar nature of the solvent used

    • Polar nature of the stationary phase

    • Polar nature of the sample

    • Conditions of the experiment

    Rf values are therefore not exactly reproducible from one experiment to another, even if an effort is made to carry them under the exact same conditions. When comparing two or more substances, they must be run simultaneously on the same plate or the comparison is invalid.